HUECK Lava 77-60

-T60-1 with smoke protection and fire protection closure
-T60-2 with smoke protection and fire protection closure
-T60 - fire resistant glazing
-Airborne sound insulation single-wing Rw <43dB; double-wing Rw <44dB
-Burglar resistance RC2 / RC2N

Construction

  • Thermally insulated aluminium fire protection construction
    in accordance with DIN 4102-5 and DIN EN 1634-1 (T60-1 / -2 -FSA and T60-1 / -2 -RS-FSA) for single- and double-leaf doors,
    opening in or out in Germany with case-by-case approval
    F60 fire-resistant glazing in accordance with DIN 4102-13 and EN 1634-1 in Germany with case-by-case approval

Sizes / dimensions

  • single-leaf: max. clearance W x H 1400 x 2534 mm
  • double-leaf: max. clearance W x H 2500 x 2534 mm
  • Element height of walls (fixed glazing) up to 3500 mm
  • Glass dimensions: up to max. 1250 x 2550 mm, upright and
    horizontal format.
  • Panel dimensions: max. 571 x 2527 mm in upright format
  • leaf weight up to 250 kg

Profile depth

  • Fixed / leaf frame 77 mm